Single phase off grid inverter
DESCRIPTION
BN series Single phase off grid inverter adopt the combination technology of integrating traditional isolated UPS function and solar inverter to provide the flexible and reliable system solution for residential or industrial uninterruptible power requirements
| 1024E | 1524E | 2024E | 3024E | ||||
| Line mode specifications | 220 V/230 V Vac ±2 % | ||||||
| AC input voltage | 155 Vac~ 272 Vac±2 % | ||||||
| Frequency | 50 Hz/60 Hz(Audio detection) | ||||||
| Frequency range | 47+0.3Hz ~55+0.3 Hz for 50 Hz;57+0.3 Hz ?65+0.3 Hz for 60 Hz | ||||||
| Over load/short protection | Circuit Breaker | ||||||
| Efficiency | > 95 % | ||||||
| Transfer time | 10 ms(typical) | ||||||
| Max Bypass over load current | 30 A | ||||||
| Invert mode | |||||||
| Output voltage waveform | Sine wave | ||||||
| Rated output power (VA) | 1000 | 1500 | 2000 | 3000 | |||
| Rated output power (W) | 1000 | 1500 | 2000 | 3000 | |||
| Power factor | 1 | ||||||
| Output voltage (V) | 230 V ac | ||||||
| Output voltage regulation | ± 10 % | ||||||
| Output frequency (Hz) | 50 Hz ±0.3 Hz/60 Hz ±0.3 Hz 10 % | ||||||
| Efficiency | > 80 % | ||||||
| Overe load protection | (110 % < load < 125 %) ±10 % : Fault (shut down output )after 15 minuts: (125 % < load <150 %) ±10 % :fault (shut down output ) after 60 s : load> 150 % ±10 % : fault (shutdown output ) after 20 s | ||||||
| Surge ratings(10 s) | 3000 VA | 4500 VA | 6000 VA | 11000 VA | |||
| Capable of starting electric motor | 1 HP | 2 HP | |||||
| Output short circuit protection | Current limit(fault after 10s) | ||||||
| Bypass breaker size | 10 A | 30 A | |||||
| Nominal DC input voltage/min DC start voltge |
24V/22V | ||||||
| DC voltage range | 20.0 V dc~30 Vdc,± 0.60V dc regultion (low alarm :21 v ;20 V high fault :32 V ;High Recovery | ||||||
| POwer saver | Load ≤ 25 W (Enabled on "P/S auto " setting of remote control):31 V | ||||||
| AC OUTPUT 2 (LOAD) | |||||||
| Charge current | 20 A | 25 A | 35 A | 50 A | |||
| Charge current regulation | ±5dc | ||||||
| Baterry initial voltage | 20-31.4 V dc | ||||||
| Charger short circuit protection | Circuit breaker | ||||||
| Breaker size | 30 A | ||||||
| Over charge protection | Over charge protection Bat.V ≥ 31.4 V dc beeps 0.5 s ever 1 s & fult after 60 | ||||||
| Charger (solar) | |||||||
| MPPT voltage range | 15-90 V | ||||||
| Max PV open circuit voltage | 90 V | ||||||
| Rated charge current | 50 A | ||||||
| Efficiency | 98% | ||||||
| Overload protection (DC load ) | 2.0 x nom > 20 s,1.5 nom temperture control | ||||||
| Baterry temperature sensor | BTS-optional remote battery temperture sesor for increased charging precision | ||||||
| Standby power consumption; | 5 W | ||||||
| General specifications | |||||||
| Safety Certification /EMC classification | CE(EN62040-1),EN62042-2,C2 | ||||||
| Protection class | IP20 | ||||||
| Operating temperature range | 150º C TO 40º C (-25º C~ 60º C for storage) | ||||||
| Operation humidity | 5 % to 95 % | ||||||
| Audible noise | 60 dB max | ||||||
| Commmunication; | RS-485/RS-232/Remote control | ||||||
| Size | 381 mm x 217 mm x179 mm | 461 mm x 217 mm x 179 mm | |||||
FEATURES
Protection class IP20
Isolated internal transformer design to ensure the stability and reliability
Capable of providing the continuous power to linear load or non-linear load of lamp, computer , fridge ,air-conditioner and the industrial device
MPPT solar charging technology
Electricity Quick charging function
Multiple charging voltage grads to adopt to more battery Topology’s, to maximize battery performance
Overload and short circuit protection
Multiple working mode are optional for different working priority (grid /battery/saving mode )
User friendly multiple communication module( RS485,RS232,Ethernet,GPRS ,WIFI ) are optional to be compatible with more monitoring device : mobile :computer ,internet /remote option
Support 12/24 V battery , 120 V/230V(50/60 Hz)