Solar pumping inverter

DESCRIPTION

BPD Series solar Water pump inverter adopts the dynamic VIMPPT technology and motor control technology and is suitable for AC water pumps with prompt response high efficiency and stable performance

BPD0K7TN BPD1K5TN BPD2K2TN BPD0K7TNAC BPD1K5TNAC BPD2KTNAAC
Input DC
Max DC voltage(V) 450 450 450 450
Starting voltage (V) 80 100 80 100
Minimum working voltage(V) 60 80 60 80
MPPT operating voltage
range(V)
80-400 100-400 80-400 100-400
Number of MPPT 1
Max C current (A) 9 12 12 9 12 12
Bypass input (AC)
Input Voltage(VAC) N/A 220/230/240
(1 HP)
-15% +10%
Input frequency (Hz) N/A 47-63
Input connect method (AC) N/A 1P2L
Output (AC)
Rated power (W) 750 1500 2200 750 1500 2200
Rated current (A) 5.1(1PH)
4.2(3 PH)
10.2(1PH)
7.5(1PH)
14(1PH)
10(3PH)
5.1(1PH)
4.2(3PH)
10.2 (1PH)
7.5 (3 PH)
14(1PH)
10(3 PH)
Output connect method 1P2L/3P3L
Output freqency (Hz) 1-400
Performance
Control mode Motor control technology
Toplogy of motor Asynchronous machines
Other Parmeter
Dimensions ( H x w x D mm) 280 x 300 x 130
Weight (kg) ≤ 10.5
Degree of protection IP65
Cooling method Natural cooling methode
HMI LED screen extend (not support LCD screen)
Communication
External communication RS 485 /3 digital inputs
Certifications
Certifications/td> CE: IEC61800-3 C3
Working environment
Ambient temperature - 25 ºC to +60ºC (derate after 45 ºc )
Working altitude 3000 m (more than 2000 m deating)
Design life 5 years (warrnty 18 months)
Recommended solar
array configuration
250 Wp (open circuit
voltage 38 V ±3 V)
certifications
4*1 8*1 11*1 4*1 8*1 11*1
300 Wp (open circuit
voltage 45±3 V)
3*1 6*1 9*1 3*1 6*1 9*1
FEATURES

Support driving single phase motor and three phase 220 V motor

One pump inverter can be connected with multiple pumps support vector control

Protection class IP65 and fan less system design with convenient installation maintenance free

Bypass function optional support 220 V utility power input and diesel engine output ; optional water level detection module and diesel engine start /stop module

Low start up voltage and wide input range give more possibilities for accepting multi PV string configuration and different Topology of PV module, save OV module cost

Digital intelligent control can flexibly adjust and set the pump speed range in addition to the soft start function it can also provide lightning protection over voltage ,over current ,over load protection function etc

ISO 9001:2015 JAS- ANZ brust-pucker
Power Systems brust-pucker
Tele Communication Systems brust-pucker
IEC Standard 61300-3-3--5 brust-pucker
Quality Management brust-pucker
Quality Control brust-pucker